Guards shall be provided where appliance equipment fans roof hatch openings or other components that require service are located within 10 feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches above floor roof or grade below.
Roof edge guardrail requirements.
Conventional fall protection guardrail fall restraint or fall arrest system is required.
For general industry working at a 4 foot height or a low sloped roof osha requires.
The top edge height may exceed 45 inches 1 14 m provided the guardrail system meets all other criteria of paragraph b of this section.
In addition the code continues to specifically address fall protection near mechanical equipment which is where the edge accufit safety railing was being placed to protect requirements stating guards shall be provided where various components that require service are located within 10 feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches 762mm above the floor roof or grade below.
The guard shall extend not less than 30.
Industry standard says that protection must be in place for anyone working within 15 feet of the roof edge.
The top edge height may exceed 45 inches 114 cm provided the guardrail system meets all other criteria of paragraph b of this section see figure d 11 of this section.
The best solution and the simplest is to install roof edge guard railing around the trouble spots to eliminate the fall hazard completely.
Osha 1910 29 b contains system requirements that employers must follow to ensure guardrail systems will protect workers from falling to lower levels.
Top edge height of top rails or equivalent guardrail system members shall be 42 inches 1 1 m plus or minus 3 inches 8 cm above the walking working level.
Conventional fall protection guardrail fall restraint or fall arrest system is required.
The top edge height of top rails or equivalent guardrail system members are 42 inches 107 cm plus or minus 3 inches 8 cm above the walking working surface.
Between 6 feet and 15 feet from the edge.
1910 29 b 3 osha requires that guardrail systems must be able to withstand a force of at least 200 lbs of point load without failure.
1910 29 b 1 the top edge height of top rails or equivalent guardrail system members are 42 inches 107 cm plus or minus 3 inches 8 cm above the walking working surface.
When conditions warrant the height of the top edge may exceed the 45 inch height provided the guardrail system meets all other criteria of this paragraph.
The top edge height may exceed 45 inches 114 cm provided the guardrail system meets all other criteria of paragraph b of this section see figure d 11 below.
Osha requires that workers exposed to a fall hazard must have fall protection.
Each roof railing system is designed by a sales engineer to ensure the highest level of safety.
From the adjacent walking surfaces.
Keeguard roof railing exceeds this requirement and has the testing documents to prove it.