Roof Sheathing Span Rating

Inspecting Roof Panel Sheathing Internachi

Inspecting Roof Panel Sheathing Internachi

Long Span Roof Sheathing Structural Engineering General Discussion Eng Tips

Long Span Roof Sheathing Structural Engineering General Discussion Eng Tips

Strength Axis In Wood Structural Panels Sbc Magazine

Strength Axis In Wood Structural Panels Sbc Magazine

Roof Sheathing Spans Internachi

Roof Sheathing Spans Internachi

Apa Rated Sheathing Structural 1 Sheathing Pages 1 5 Text Version Fliphtml5

Apa Rated Sheathing Structural 1 Sheathing Pages 1 5 Text Version Fliphtml5

Km 7fw4p Ofgpm

Km 7fw4p Ofgpm

Km 7fw4p Ofgpm

Sheathing panels 3 8 category may be installed perpendicular or parallel to supports spaced a maximum of 16 o c and will support a 30 psf live load without exceeding a deflection limit of 1 180.

Roof sheathing span rating.

Loads will vary with the pitch of the roof. Apa rated sheathing panels are produced as plywood or oriented strand board osb. The span rating indicates the maximum center to center spacing in inches of support over which panels can be installed. Commonly square edge but may be produced with tongue and groove edges.

2 4 common performance categories and corresponding span ratings performance category span rating 3 8 24 0 7 16 24 16. All rated siding panels may be applied horizontally direct to studs 16 or 24 inches on center provided horizontal joints are blocked. That will suffice on a roof with rafters set 16 inches apart with minimal roof loads. Floor or roof sheathing conforming with this table shall be deemed to meet the design criteria of section 2304 7.

Panels are available that carry apa series mobile home roof sheathing rating n 216r. The first number is the maximum on center o c support spacing in inches for roof sheathing. 1 inch 25 4 mm. Installation details shall conform to sections 2304 7 1 and 2304 7 2 for floor and roof sheathing respectively.

Allowable spans for lumber floor and roof sheathing a b for si. Panels and lap siding bearing a span rating of 24 oc may be used direct to studs 24 inches on center. The first number represents the maximum support spacing for a roof application and the second number indicates a maximum spacing of supports for flooring. The span rating on sheathing span panels appears as two numbers separated by a slash e g 32 16 or 48 24.

Span ratings span rating numbers for sheathing span and floor span indicate the maximum spacing of supports over which the panels should be placed. Panels and lap siding with a span rating of 16 oc may be applied direct to studs spaced 16 inches on center. Roof sheathing attaches to the surface of the rafters or trusses to form the structural skin of the roof. Common roof sheathing applications and installation recommendations are described in the related publications listed at right.

Most roofs will be sheathed in plywood at least 3 8 inch thick. Some products feature a two span rating such as 24 16. It spans the rafters to support the roofing and in the case of panel sheathing such as plywood or osb it acts as a diaphragm with the walls to resist horizontal loads. Multi span normal duration of load dry conditions panels 24 inches or wider span rating b load governed by c strength axis a perpendicular to supports span center to center of supports inches parallel to supports span center to center of supports inches 12 16 19 2 24 30 32 36 40 48.

Myicc

Myicc

Pscl Psca Panel Sheathing Clips Simpson Strong Tie

Pscl Psca Panel Sheathing Clips Simpson Strong Tie

2006 International Building Code

2006 International Building Code

Image Result For Plywood Span Rating Tongue And Groove Panelling Tongue And Groove Lumber

Image Result For Plywood Span Rating Tongue And Groove Panelling Tongue And Groove Lumber

Source : pinterest.com